BELUK Power Quality Instruments |
|
The Beluk family of products consist of the BLR series of Power Factor Controllers, KSR Capacitor Protection Relay and EMM 5 Power Analyzer. For additional information, please click the link to our download page where PDF files of bulletins and installation instructions for most instruments may be found. Extra detail is included on this page for the BLR-CX along with a specific link to obtain the complete instruction manual for the unit. Additional products from Beluk are accessories to the power factor correction function such as software and data loggers for the BLR series plus static contactors. Please contact Illimite directly for information on these items.
|
|
The BLR-CX Power Factor Controller |
|
|
|
BLR-CX Standard Features n 4-quadrant measurement of reactive and constant supervision of inductive / capacitive load n measurement and supervision of each step of kvar output during switching process n adjustment of transformer ratios for control purposes is not required on standard models. n adjustment of target cos phi in the range of 0.70 (lag) to 1.0 to 0.90 (lead) n adjustable switching time from 5 to 1200 seconds n manual switching may be selected whenever required n no-volt release with power interruption greater than 35 ms. n 90 second lockout time following power failure and subsequent power restoration. n optical (LED) indication of each individual stage n display of measured power factor n failure alarm if target cos j is not achieved (after completion of 75 switching cycles) n instrument may be connected in either a three phase system or a single phase n available in 4, 6, 8 or 12 step models n asymmetrical switching time delays are user programmable n automatic alarm indication of failed steps n automatic and “1111” (first in, last out - last in, first out) switching programs are user selectable |
|
|
|
The lower image is the BLR-CX-M or BLR-CX-L-M. The “M” option adds the capability to select and display measured electrical system values in addition to the standard display of power factor. In order to accurately display system parameters, the CT and PT ratios must be entered into the instrument: this is performed using the “+” and “-” touch pads and only has to be entered one time as the values are stored in non-volatile memory. The BLR unit will normally display the measured power factor but at any time a user can select voltage, current, total active power, total reactive power or frequency using the same + and - pads. The selected parameter will be displayed until the user chooses to return the selection to power factor or other system value. |
|
|
![]() |
||||||||
![]() |
||||||||
|
Connection of all wiring is made by pushing down on a “tab” next to each conductor’s location; this opens the wire clamp cage allowing a stripped wire to enter, releasing the ‘tab’ again retains the wire through the cage’s spring pressure and the connection is complete. This time saving method uses a small flat blade screwdriver to apply the pressure to the tab. |
||||||||
![]() |
||||||||
|
A panel cutout of 138 x 138 mm is required to mount the BLR-CX. For retrofit applications where an existing 137 x 137 mm opening is to be used, 8 small locating tabs are simply removed and the instrument will fit precisely. Two mounting clamps are molded into the instrument case providing fast and secure retention of the BLR-CX in the panel or cabinet. |
||||||||
|
Please note that the instruments below have been discontinued and the details are provided for existing users -- for information on the NEW BLR-CM (not shown) - Please contact Illimite by email - thanks! |
|||||||||||||||||||
![]() |
![]() |
||||||||||||||||||
![]() |
|||||||||||||||||||
![]() |
|||||||||||||||||||
|
BLR-CA BLR-CB BLR-CC BLR-CM |
|||||||||||||||||||
|
When developing the BLR series of power factor controllers, the Beluk engineerinig staff attached great importance to simplicity of installation and operation . With the new design of the products, each instrument automatically sets up after a few simple switch settings by the installer. It is no longer necessary to select the starting current (C/k value) or a fixed switching program. |
|||||||||||||||||||
Common Features on - CA, - CB, - CC, and - CM models |
|||||||||||||||||||
|
Model Specific Features BLR-CA BLR-CB BLR-CC BLR-CM |
|||||||||||||||||||
|
To receive a copy of a complete BLR installation manual for these discontinued instruments, please send an email with BLR in the subject line and your name, company name and phone in the text - we will send you a PDF file in return - Click the envelope to begin your email:
|
|||||||||||||||||||